The City of Kamloops uses the MMCD 2019 Edition. All construction works shall conform to:
- The MMCD 2019 Edition,
- All City of Kamloops Amendments,
- The City of Kamloops Approved Products List, and
- The following list of Standard Detail Drawings
This information is supplementary to Volume II of the Master Municipal Construction Documents published by the M.M.C.D.A., 2019. All civil construction projects for municipal ownership are to comply with the following supplemental construction criteria:
Amendments to MMCD - 2013 | |
---|---|
MMCD 2009 to 2019 Edition Change Summary | January 2025 |
List of Approved Products and Materials | January 2025 |
MMCD Amendments* | January 2025 |
Supplemental Standard Detail Drawings | December 2024** |
Standard Survey Requirements | March 2014 |
Water/Sewer/Drainage Electrical Specifications | November 2014 |
Water Main Testing Procedure | January 2025 |
*Supplementary Specifications
**Last update to one or more drawings
For Unit Price Contract - Consultant (amended March 2016), please contact Matt Kachel, the City's Infrastructure Delivery Divisional Manager, at 250-828-3532.
Supplemental Standard Detail Drawings | ||||
---|---|---|---|---|
Concrete and Miscellaneous Details | ||||
# | Revision | Title | Comment | Approved |
C0 | Drawing Index - Concrete and Miscellaneous Details | MMCD | ||
SC1 | 5 | Monolithic Curb, Gutter & Sidewalk | Replaces C1-C3 | Feb 2022 |
C4 | Concrete Curbs - Narrow Base | MMCD | ||
C5 | Concrete Curbs - Wide Base | MMCD | ||
C6 | Concrete Median and Interim Curbs | MMCD | ||
SC7 | 7 | Driveway Crossing at Sidewalks and Curbs | CoK Supplemental | Apr 2022 |
SC8/SC9 | 5 | Wheelchair Ramp | CoK Supplemental | Oct 2022 |
SC10 | 6 | Multi-use Pathways | CoK Supplemental | Mar 2023 |
SC11 | 4 | Bicycle Baffle | CoK Supplemental | Feb 2022 |
C12 | Removable Barrier Post | MMCD | ||
C13 | Chain Link Fence for Walkway | MMCD | ||
SC14 | 3 | Handrail on Concrete Retaining Wall | CoK Supplemental | Feb 2022 |
SC15 | 3 | Wooden Fence for Multi-use Pathways | Additional | Feb 2022 |
SC16 | 4 | Tree Planting Detail | Additional | Dec 2022 |
SC17 | 3 | Access Gate | Additional | Apr 2022 |
SC18 | 3 | No Public Access Signage | Additional | Feb 2022 |
SC19 | 2 | Decorative Brick | Additional | Apr 2022 |
Concrete Base | ||||
# | Revision | Title | Comment | Approved |
CE1.1 | Concrete Base Index | MMCD | ||
CE1.2 | Type A and B Sonotube Concrete Bases | Delete | ||
CE1.21 | 2 | Custom Sonotube Concrete Base | CoK Supplemental | Jan 2025 |
CE1.3-1.4 | Type C,C1,C2,C3 Trapezoidal Shape Concrete Bases | MMCD Supplementary Update | ||
CE1.5 | Type C4 & C5 Spread Footing Shape Concrete Bases | MMCD Supplementary Update | ||
CE1.6 | Type C4 & C5 Spread Footing Concrete Bases | MMCD | ||
CE1.7 | Type C4 & C5 Spread Footing Concrete Bases | MMCD Supplementary Update | ||
CE1.8-1.9 | Type E2 Trapezoidal Shape Concrete Base | MMCD | ||
CE1.10-1.12 | Types F1,L1,S1 Spread Footing Shape Concrete Bases | MMCD | ||
CE1.13-1.14 | Types F2,L2,S2 Trapezoidal Shape Concrete Base | MMCD | ||
CE1.15 | 25mm Anchor Bolts | MMCD | ||
CE1.16 | Anchor Bolt Cage for Types 6, 7 & S Poles | MMCD | ||
CE1.17 | Anchor Bolt Cage for Type L Poles | MMCD | ||
CE1.18 | Concrete Base for Post Mounted Flasher Luminaire (Precast) | Delete | ||
CE1.19-1.20 | Pole Base Installation Details | MMCD | ||
Electrical | ||||
# | Revision | Title | Comment | Approved |
E0.1-0.2 | Drawing Index - Electrical Drawings | MMCD | ||
SE1.1 | Type M (Nema Cabinet) Concrete Controller Base | Delete | ||
SE1.2 | 1 | Type P (Nema Cabinet) Concrete Controller Base | CoK Supplemental | Apr 2015 |
E1.3 | Model 170 Concrete Controller Base | Delete | ||
SE1.4 | 1 | Controller Installation (Type P & M Cabinets | CoK Supplemental | Apr 2015 |
E1.5 | Controller Installation (Model 170 Cabinets) | Delete | ||
E1.6-1.7 | Type F Control Pedestal | Delete | ||
E2.1 | Round Plastic Junction Boxes | Delete | ||
SE2.2 | 2 | Junction Box Section | CoK Supplemental | Jan 2025 |
E2.3-2.4 | Large Concrete Junction Boxes | MMCD | ||
E2.5-2.6 | Concrete Vault | MMCD | ||
SE3.1 | 1 | Trench Details & Installation Notes (Paved Areas) | CoK Supplemental | Jan 2025 |
SE3.2 | 2 | Trench Details & Installation Notes (Unpaved Areas) | CoK Supplemental | Jan 2025 |
SE4.1 | 2 | Street Light Road/Sidewalk Section | CoK Supplemental | Jan 2025 |
E4.2 | Luminaire Pole (Type 2 Shaft) | MMCD | ||
E4.3-4.4 | Signal Pole (Type 1 Shaft) | MMCD | ||
E4.5-4.6 | Signal Pole (Type 3 Shaft) | MMCD | ||
E4.7-4.8 | Signal Pole (Type 6 Shaft) | MMCD | ||
E4.9-4.10 | Signal Pole (Type 7 Shaft) | MMCD | ||
E4.11-4.13 | Signal Pole (Type S Shaft) | MMCD | ||
E4.14-4.16 | Signal Pole (Type L Shaft) | MMCD | ||
SE4.17 | 2 | Signal Posts Type 4A | CoK Supplemental | Mar 2014 |
SE4.18 | 1 | Signal Posts Type 4A | CoK Supplemental | Jan 2011 |
E4.23 | Post Top Luminaire Poles | MMCD | Jan 2025 | |
E4.24 | Service Base | MMCD | Jan 2025 | |
E4.25 | Pole Accessories | MMCD | Jan 2025 | |
SE4.26 | 2 | Type 2 & 3 Luminaire Layout Street View | CoK Supplemental | Jan 2025 |
SE4.27 | 2 | Typical Multi-Use Street Light Road/Sidewalk Section | CoK Supplemental | Jan 2025 |
SE4.28 | 2 | Long Arm Street Light Road/Sidewalk Section | CoK Supplemental | Jan 2025 |
SE4.29 | 2 | Long Arm Street Light With Multi-Use Path Light Road/Sidewalk Section | CoK Supplemental | Jan 2025 |
E5.1 | Post Top Signal Head Mounting | Delete | ||
E5.2 | Side of Pole Signal Head Mounting (Method 1) | MMCD | ||
E5.3-5.6 | Various Signal Head Mounting Methods | Delete | ||
E5.7 | Mid Span Overhead Signal Mounting (Plumbizer Method) | Delete | Jan 2025 | |
E5.8 | Overhead Signal Head Mounting (Plumbizer Method) | Delete | Jan 2025 | |
E5.9 | Overhead Signal Head Mounting (Adjustable Bracket Method) | Delete | ||
E5.10-5.11 | Overhead Signal Head Mounting on Pole Arm (Ball Hanger Method) | Delete | ||
E5.12 | Audible Signals | Delete | ||
E5.13 | Video Detection Installation Detail on Special 2A Arm | MMCD | ||
SE5.14 | Video Detection Installation Detail on Signal Arm | CoK Supplemental | Feb 2011 | |
SE5.15 | Internally Illuminated Pedestrian Crosswalk Sign | Delete | Jan 2025 | |
E6.1 | Pedestrian Pushbutton with Separate Sign | Delete | ||
SE6.2 | Pedestrian Pushbutton with Integral Sign | Delete | Jan 2025 | |
E6.3 | Pedestrian Pushbutton Post | MMCD | ||
E7.1 | Underground Dip Service | Delete | Jan 2025 | |
E7.2-7.3 | Service Panel in Service Base (Mounting Details) | Delete | Jan 2025 | |
E7.4 | 60A Streetlight and 100A Streetlight/Traffic Signal S.P. (Panel Details) | Delete | Jan 2025 | |
E7.5 | 40A (120/240V) Street Lighting S.P. (Wiring Diagram) | Delete | Jan 2025 | |
E7.6 | 100A or 60A (120/240V) Traffic Signal and/or Street Lighting S.P. (Wiring Diagram) | Delete | Jan 2025 | |
E7.7 | 100A Traffic Signal/Streetlight Service Panel on Pole (Mounting Details) | Delete | Jan 2025 | |
E7.8 | 100A Traffic Signal/Streetlight Service Panel on Pole (Mounting Details) | Delete | Jan 2025 | |
E7.9 | 100A (120/240V) Traffic Signal/Street Lighting S.P. (Wiring Diagram) | Delete | Jan 2025 | |
E7.10 | Service Ground Plate Installation Detail | Delete | Jan 2025 | |
E7.11 | Luminaire Wiring in Pole Handhole | Delete | Jan 2025 | |
E7.12 | Signal Cable Wiring in Pole Handhole | Delete | Jan 2025 | |
SE7.13 | 2 | Traffic Signal Wiring Color Code | CoK Supplemental | Mar 2014 |
E7.14 | Minimum Clearances to Overhead Powerlines | Delete | Jan 2025 | |
E7.15 | Pole Mounted Receptacle | Delete | Jan 2025 | |
E7.16 | Telephone Demarcation Enclosure Mounting Details | Delete | Jan 2025 | |
E7.17 | Telephone Conduit on Utility Pole | Delete | Jan 2025 | |
E7.18 | Conduit Tie-In to Telephone Vault, Manhole or Junction Box | Delete | Jan 2025 | |
SE7.19 | 2 | Typical 1Ø Kiosk Configuration | CoK Supplemental | Jan 2025 |
SE7.20 | 2 | 1Ø Metering Kiosk Bill Of Materials & Single Line Diagram | CoK Supplemental | Jan 2025 |
SE7.21 | 2 | Typical Lighting Control Schematic For MUP Poles | CoK Supplemental | Jan 2025 |
E8.1 | Typical Detector Loop Types | Delete | Jan 2025 | |
E8.2 | Detector Loops | Delete | Jan 2025 | |
E8.3 | Detector Loops | Delete | Jan 2025 | |
E8.4 | Detector Loop to Shielded Cable Splices | Delete | Jan 2025 | |
E8.5 | Detector Loop Procedures and Rules | Delete | Jan 2025 | |
E8.6 | Detector Loop Procedures and Rules | Delete | Jan 2025 | |
SE8.12 | Typical Traffic Counting Station | Delete | Jan 2025 | |
E8.8 | Pre-Formed Diamond Detector Loop Installation Details | Delete | ||
E8.9 | Pre-Formed Diamond Detector Loop Installation Details | Delete | ||
E8.10 | Pre-Formed Diamond Detector Loop Installation Details | Delete | ||
E9.1 | Flasher Luminaire and Signs on Perforated Steel Tubing | Delete | ||
E9.2 | Flasher Luminaire and Signs on Perforated Steel Tubing | Delete | ||
E9.3 | Flasher Luminaire and Signs on Steel Pole | Delete | ||
E9.4 | Flasher Luminaire and Signs on Steel Pole | Delete | ||
E10.1-10.2 | Overhead Extruded Aluminum Advance Warning Sign | MMCD | ||
SE10.3 | 0 | Overhead Extruded Aluminum Advance Warning Sign Installation Details | CoK Supplemental | Jan 2011 |
E10.4-10.8 | Overhead Extruded Aluminum Sign | MMCD | ||
E10.9 | Overhead Extruded Aluminum Sign Luminaire | MMCD | ||
E10.10 | Junction Box Installation Details on Sign Arms | MMCD | ||
General Details | ||||
# | Revision | Title | Content | Approved |
G0 | Drawing Index - General Details | MMCD | ||
G1 | General Legend for Contract Drawings | MMCD | ||
G2 | Legend for Materials | MMCD | ||
SG3 | 1 | Legend for Streetlights and Signals | CoK Supplemental | Dec 2010 |
SG4 | 5 | Utility Trench | CoK Supplemental | Oct 2024 |
SG5 | 4 | Pavement Restoration | CoK Supplemental | Feb 2022 |
G6 | Concrete Encasement Watermain/Sewer Separation | MMCD | ||
G7 | Concrete Protection Underground Utilities | MMCD | ||
G8 | Pipe Anchor Blocks | MMCD | ||
SG9 | 4 | Utility Offsets for Urban R/W | Additional | Oct 2023 |
SG10 | 4 | Utility Servicing in a Cul-De-Sac | Additional | Aug 2022 |
SG11 | 3 | Service Locations Standards for S.F.D. Residential Lot | Additional | Apr 2022 |
SG12 | 6 | Project Sign | Additional | Jan 2019 |
SG13 | 2 | Typical Traffic Sign Installation | Additional | Oct 2024 |
Roadworks | ||||
# | Revision | Title | Content | Approved |
R0 | Drawing Index - Roadworks | MMCD | ||
R1 | Paved Shoulders | MMCD | ||
R2 | Driveway Letdowns, Cross-Section | Delete | ||
R3 | Sidewalks, Interim Asphalt | Delete | ||
R4 | Single Ramp Letdown with Parallel Scoring | Delete | ||
R5 | Traffic Calming, Speed Hump and Table | MMCD | ||
R6 | Traffic Calming, Raised Intersection Details | Delete | ||
R7 | Traffic Calming, Typical Raised Median | Delete | ||
R8 | Traffic Calming, Curb Extensions and On-Street Parking Bay | Delete | ||
Storm and Sanitary Sewers | ||||
# | Revision | Title | Comment | Approved |
S0 | Drawing Index - Storm and Sanitary Sewers | MMCD | ||
SS1 | 1 | Standard Manholes | CoK Supplemental | Mar 2022 |
S2 | Standard Manhole Connection Details | MMCD | ||
S3 | Manhole Connection Details - Drop and Ramp Type | Delete | ||
SS4 | 2 | Inside Drop Manhole | CoK Supplemental | Mar 2022 |
S5 | Precast Riser Manhole | MMCD | ||
SS5a | Cast in Place Manhole for 375-1200 Sewers | Delete | ||
S6 | Sewer Cleanout | Delete | ||
SS7 | 4 | Sanitary Sewer Service Connection | CoK Supplemental | Apr 2022 |
SS8 | 5 | Storm Sewer Service Connection | CoK Supplemental | Mar 2022 |
SS9 | 3 | Inspection Chamber for Sanitary and Storm Sewer Connections | CoK Supplemental | Apr 2022 |
S10 | Inspection Chamber for 250-375mm Storm, Sewer Connections | Delete | ||
SS11a | 6 | Catch Basin - Type I | CoK Supplemental | Mar 2022 |
SS11b | 5 | Catch Basin - Type II | CoK Supplemental | Mar 2022 |
SS11c | 3 | Catch Basin - Type III | CoK Supplemental | Mar 2022 |
SS12a | 3 | Lawn Drains | CoK Supplemental | Apr 2022 |
SS12b | 1 | Drywell Structure | CoK Supplemental | Apr 2022 |
SS13 | 3 | Concrete Headwall | CoK Supplemental | Jan 2019 |
SS14 | 4 | Headwall Grillage | CoK Supplemental | Mar 2023 |
SS15 | 1 | Driveway Culvert With Concrete Headwalls 300–600mm | Mar 2023 | |
S16 | Asphalt Aprons for Catch Basins | Delete | ||
S17 | Subdrain | MMCD | ||
Waterworks | ||||
# | Revision | Title | Comment | Approved |
W0 | Drawing Index - Waterworks | MMCD | ||
SW1 | 0 | Typical Thrust Block Arrangements | CoK Supplemental | Feb 2019 |
SW2 | 7 | Water Service Connection (25-50mm Dia) | CoK Supplemental | Jun 2022 |
SW2c | 2 | Typical Outdoor Water Meter Pit | CoK Supplemental | Nov 2024 |
SW2d | 2 | Frostproof 19mm and 25mm Meter Vault | CoK Supplemental | Nov 2024 |
W2a-W2d | Water Service Connections and Water Meters | Delete | ||
SW3 | 3 | Gate Valve Installation | CoK Supplemental | Apr 2022 |
SW4 | 8 | Fire Hydrant Assembly | CoK Supplemental | Nov 2022 |
W5 | Test Point Installation | MMCD | ||
SW6/SW7 | 5 | Air Release Valve Chamber | CoK Supplemental | Nov 2024 |
SW6/SW7b | 1 | Air Release Valve Chamber for Large Diameter Mains | CoK Supplemental | Nov 2024 |
SW8 | 7 | Self-Draining Standpipe (Buried) & Corrosion Protection | CoK Supplemental | Apr 2022 |
W9 | Blow-Down Chamber | MMCD | ||
W10 | Waterworks Chamber Drain | MMCD | ||
SW11 | 5 | Butterfly Valve Chamber | Additional | Nov 2024 |
SW12 | Permanent Water Sampling Station | CoK Supplemental | July 2023 | |
SW13 | Watermain Relocation | Delete | ||
SW14 | 1 | Irrigation Point of Connection | Additional | Mar 2023 |
SW15 | 1 | Water Service Corrosion Protection | Delete | |
SW16 | 4 | Two Anode Installation | Additional | Apr 2022 |
SW16a | 4 | Typical Two Anode Installation with Test Station | Additional | Dec 2024 |
SW17 | Flush Mounted Monitoring Test Station | Delete | ||
Cathodic Protection | ||||
# | Revision | Title | Comment | Approved |
W100 | Drawing Index - Cathodic Protection | MMCD | ||
W104 | Ground Level Test Station Details | Delete | ||
W105 | Big Fink Test Station Terminal | Delete | ||
W106 | Joint Continuity Bond | Delete | ||
SW104 | 2 | Ground Level Test Station Details | CoK Supplemental | Dec 2024 |
SW107 | 2 | Structure Cable Bond Detail | CoK Supplemental | Apr 2022 |
SW107a | 2 | Structure Cable Bond Detail with Test Station | Additional | Dec 2024 |
W108 | Standard Test Station | Delete | ||
W109 | Isolation Test Station | Delete | ||
W110 | Standard Anode Station at Isolation Test Point | Delete | ||
SW111a | 1 | Isolated Metal Fitting Cathodic Protection Installation Single Test Station with 2 Circuits | Additional | Dec 2024 |
W112 | Sacrificial Anode with Lateral or Service Connection | Delete | ||
W113 | Foreign Utility Test Station | Delete | ||
W114 | Impressed Current Cathodic Protection Rectifier Installation | Delete | ||
W115 | Horizontal Anode Installation | Delete | ||
W116 | Semi-Deep Anode Well Installation | Delete | ||
SW119 | 3 | Hydrant Cathodic Protection | CoK Supplemental | Apr 2022 |